Supplier didn't find root cause for contamination problem,
what unable them to take corrective actions against cause of occurrence.
They decided to improve dispersion level of the compound - have supplier advised any details on this?
Supplier decided to introduce additional inspection with frequency 1 per 5 batches.
Does it mean that with standard dispersion check they could not detect this problem?
Do they advised current method of dispersion check and criterion for it?
If so, could you please let us know.
Also we would like to ask regarding affected material:
- we have around 438 kg in "isolator" - should we still keep it or we can throw it away?
- in total we had around 840 kg of affected M/B - can we get replacement?