1) Stacking is occuring on any fricuency. (Need advansed inprovement)
2) It has a sensor for stacking pieces to stop the machine (working it enough or not)
3) If operator push reset botturn without removing the stacked pieces
any additional pieces will stack on slope and move into wrong
judgement boxes (Highest Risk).
Video should inform everyone reality with very objective. however
even if you intend or not intend the fiction video or unusual status
video without any explanation will make wrong information to everyone
and bring the misjudgement on the other hand.
Please understand and review what you did.
(As you know ,dengerousity with an example propaganda video on politics///)
Dear all related
Anyway , what we have to do from this video.
1) (offcourse we'd known it so attached sensor on the slope but)
PE will try to set air blowing at the slope to prevent occurence
with less possivility.
2) It must be OK,or If shorter piece stack at the upper of slope ???
this risk will be reacted by airblowing as mentioned above in same
time.
3) Instructed Operator and Operation WI must be checked.
(If avoid this un-compliance for WI with some countermeasure,
we must put resetting potturn at the slope and operator only
can do resetting with removeing stacked pieces >>> but this is
non-sense , roof on roof issue, so keep operation compliance
to basic work will be very important.)
I think 3) issue is the most serious and fundamental problem if
our operator used to do so.